TrialX
Image

Determination of Diastolic Dysfunction by Single Lead Electrocardiogram

Determination of Diastolic Dysfunction by Single Lead Electrocardiogram

Recruiting
18-90 years
All
Phase N/A

Overview

It is a prospective, controlled, single-center, non-randomized, observational study.

From September 2019 to December 2020, the study plans to prospectively include 400 patients aged 18 to 90 years.

Every patients will undergo an echocardiographic examination with assessment diastolic dysfunction of the left ventricle, and registration of an electrocardiogram using a single lead ECG monitor CardioQvark (in I standard lead) for 3 minutes. All patients will be divided into 2 main groups: with diastolic dysfunction of the left ventricle, confirmed by the results of the echocardiography and without. A spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform.

The result of this study will be the identification of ECG parameters that will correlate with LV diastolic dysfunction.

Description

It is a prospective, controlled, single-center, non-randomized, observational study.

From September 2019 to December 2020, the study plans to prospectively include 400 patients aged 18 to 90 years.

The goal of study is reveal single parameters of the electrocardiogram, which a good correlation with left ventricular diastolic dysfunction (LV DD), discovered during echocardiography.

Investigators plan to assess the diagnostic effectiveness of the spectral analysis of electrocardiograms obtained using a single-lead portable ECG monitor.

All subjects will undergo an echocardiographic examination of the heart with a determination of diastolic dysfunction of the left ventricle and will be divided into 2 main groups: with diastolic dysfunction of the left ventricle, confirmed by the results of the echocardiography and without.

At the same time, for all patients single-lead ECG will be recorded (in turn of leads I) for 3 minutes with further spectral analysis of the data obtained.

A single-lead ECG monitor CardioQvark is designed as an iPhone cover. It is registered with the Federal Service for Health Supervision on February 15, 2019. RZN No. 2019/8124.

Then a spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform, the principles of which are based on the Fourier transform.

The analysis implies an assessment of the following parameters (the parameters listed below will be calculated as the median of the tact-cycle):

  • TpTe - time from peak to end of the T-wave
  • VAT - time from the beginning of the QRS to the R-peak
  • QTc - corrected QT interval.
  • QT / TQ - the ratio of QT length to TQ length (from the end of T to the beginning of the QRS of the next complex).
  • QRS_E - the total energy of the QRS wave based on the wavelet transform
  • T_E - T-wave total energy based on wavelet transform
  • TP_E- energy of the main tooth of the T-wave based on the wavelet transform
  • BETA, BETA_S - T-wave asymmetry coefficients (simple and smooth versions)
  • BAD_T - flag of T-wave quality (whether expressed in the current lead
  • QRS_D1_ons - energy of the leading edge of the R-wave (based on the "first derivative" wavelet transform)
  • QRS_D1_offs - energy of the trailing edge of the R-wave (based on the "first derivative" wavelet transform)
  • QRS_D2 - peak energy of the R-wave (based on the "second derivative" wavelet transform)
  • QRS_Ei (i = 1,2,3,4) - QRS-wave energy in 4 frequency ranges (2-4-8-16-32 Hz) based on wavelet transform
  • T_Ei (i = 1,2,3,4) - T-wave energy in 4 frequency ranges (2-4-6-8-10 Hz) based on wavelet transform
  • HFQRS - the amplitude of the RF components of the QRS wave

Additionally used parameters:

  • TpTe, VAT, QTc - are duplicated to control the correctness of the record processing (the value of the UCC should be approximately equal to the median of the tick-by-bar).
  • QRSw - QRS width.
  • RA, SA, TA - the amplitudes of the R, S, T-waves, respectively, are used to normalize the parameters listed above.

Statistical processing of results: SPSS Statistics Version 26 is a computer program for statistical processing of data.

The result of this study will be the identification of ECG parameters that will correlate with LV diastolic dysfunction, and by which it will be possible to determine its presence and degree in the future.

Investigators also plan to analyze ECG parameters characteristic of patients with LV diastolic dysfunction in different population groups:

  • patients suffering from high blood pressure with patients without the above pathology
  • patients with zones of a- and hypokinesis according to echocardiography as a result of a coronary circulation disorder
  • patients suffering from atrial fibrillation with patients without this pathology
  • men / women
  • patients of different age groups

During statistical processing of the data, the following will be calculated: sensitivity, specificity, prognostic value of positive and negative results, likelihood ratio, area under ROC - curve, correlation coefficient. it is planned to obtain data on the diagnostic effectiveness of the proposed approach, as well as on individual parameters of the electrocardiogram in the diagnosis of diastolic dysfunction of the left ventricle.

Eligibility

Inclusion Criteria:

  • The presence of written informed consent of the patient to participate in the study
  • Age from 18 years to 90 years
  • Outpatient treatment and / or hospitalization in a research center

Exclusion Criteria:

  • Reluctance of the patient to participate in the study
  • Poor quality ECG recording on a single-channel ECG monitor
  • Poor visualization of the heart during echocardiographic study
  • Acute psychotic reactions that arose during research
  • An exacerbation of chronic diseases requiring treatment tactics for the patient and preventing his further participation in the study.

Non-inclusion criteria:

  • The presence of conduction disturbances in patients that impede ECG analysis (WPW syndrome, sinoatrial block of degrees 2 and 3, atrioventricular block 3 degrees, complete block of the left bundle branch block, complete block of the right bundle branch block)
  • Conditions that can impair ECG recording quality (Parkinson's disease, essential tremor)
  • The inability to assess diastolic function during echocardiography
  • Mental illness
  • Diseases with an expected life expectancy of less than 2 years
  • Patients with diffuse hypokinesis of the left ventricle with a reduced ejection fraction (less than 30%)
  • Patients with a pacemaker installed

Study details
    Diastolic Function

NCT04474639

I.M. Sechenov First Moscow State Medical University

16 February 2024

Step 1 Get in touch with the nearest study center
Message sent successfully.
We have submitted the information you provided to the research team at the location you chose. For your records, we have sent a copy of the message to your email address.
If you would like to be informed of other studies that may be of interest to you, you may sign up for Patient Notification Service.
Sign up

Send a message

Enter your contact details to connect with study team


Email

View email

Phone

Phone country flag

View phone
Investigator Avatar

Primary Contact

First name*
Last name*
Email*
Phone number*
Other language

FAQs

Learn more about clinical trials

What is a clinical trial?

A clinical trial is a study designed to test specific interventions or treatments' effectiveness and safety, paving the way for new, innovative healthcare solutions.

Why should I take part in a clinical trial?

Participating in a clinical trial provides early access to potentially effective treatments and directly contributes to the healthcare advancements that benefit us all.

How long does a clinical trial take place?

The duration of clinical trials varies. Some trials last weeks, some years, depending on the phase and intention of the trial.

Do I get compensated for taking part in clinical trials?

Compensation varies per trial. Some offer payment or reimbursement for time and travel, while others may not.

How safe are clinical trials?

Clinical trials follow strict ethical guidelines and protocols to safeguard participants' health. They are closely monitored and safety reviewed regularly.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.