Validation Study of WITHINGS BPM Core for the Detection of Atrial Fibrillation

Validation Study of WITHINGS BPM Core for the Detection of Atrial Fibrillation

Recruiting
18 years and older
All
Phase N/A

Overview

The proposed clinical study aims to validate the diagnostic performance, compared to a reference ECG, of the electrocardiographic function of the BPM Core developed by Withings for the automatic identification of atrial fibrillation (AF).

Description

BPM Core is a blood-pressure monitor with an build-in single-channel electrocardiogram similar to a lead I.

Primary objective:

The primary objective is to demonstrate that Withings BPM Core has acceptable sensitivity and specificity in the automatic identification of AF and SR in comparison with a gold-standard diagnosis from a 12-lead ECG by board certified cardiologists.

The algorithm classifies the device signals into four categories: normal sinus rhythm (RSN), AF, arrhythmia other than AF, or non-interpretable. The latter category includes signals of insufficient quality to be interpreted with confidence.

This classification will be compared to the diagnosis made by three independent, blinded cardiologists based on a 12-lead ECG. The final diagnosis retained will be decided by majority with adjudication by a consensus of 3 to 6 cardiologists. The sensitivity and specificity of the device will then be estimated.

Secondary objectives:

The first secondary objective is to assess the quality of tracings of the BPM Core armband thanks to a qualitative and quantitative comparison between BPM Core tracings and reference ECG ones, based on clinical evaluation criteria.

Firstly, three independent cardiologists who have not performed or read the reference ECG and do not know the patient's clinical files will make a diagnosis from the recordings from the BPM Core. There will be a majority vote to select the diagnosis. The cases where the three readers reached three different diagnosis will be reviewed by a panel of 3 to 6 board certified cardiologists who will decide by consensus. Sensitivity and specificity will be calculated relative to the reference ECG.

Secondly, quantitative analyses will be performed to assess the quality of ECG tracings provided by Withings BPM Core and its software, as follows:

  • The visibility and polarity of the ECG waves (namely P-waves, QRS complexes and T-waves) will be determined by the cardiologists for each lead I signals recorded with Withings BPM Core and with the 12-channel ECG device. The assessment will be made on the 5th complete beat of the recording. For each of the waves (P, QRS and T), the agreement of visibility and the agreement of polarity (when both are visible) between the signals of Withings BPM Core and the reference ECG device will be computed.
  • The duration of the main ECG intervals (namely QT interval, QRS width and PR interval) will be determined by the cardiologists for each lead I signal recorded by Withings BPM Core and the 12-channel ECG device. The measurement will be made with a caliper on the 5th complete beat of the recording. For each interval (QT, QRS, PR), the difference of length between the signals of Withings BPM Core and the reference ECG device will be computed.
  • The heart rate will be first determined by the cardiologists for each lead I signal (recorded by Withings BPM Core and the 12-channel ECG device) which are diagnosed as NSR. The heart rate difference between the signals of Withings BPM Core and the reference ECG device will be computed. Second, the heart rate of the signals recorded with the BPM Core will be computed by the Withings software. The difference between the heart rate estimated by Withings software on Withings BPM Core signals and the heart rate determined by the cardiologists on the lead I signal from the ECG reference device will also be calculated.

The sponsor will make sure that the same cardiologist will not be asked to annotate both a Withings BPM Core signal and the corresponding lead I signal from the 12-channel ECG device. The sponsor will then centralize the annotations of Withings BPM Core tracings and of the ECG reference lead I signals and perform agreement calculations on synchronous pairs.

The second secondary objective is to verify the safety of use of the device by analyzing adverse effects.

The safety of use of the device will be assessed by the number of adverse effects.

Eligibility

Inclusion Criteria:

  • male or female who are 18 years or older
  • Subject who signed the written informed consent form,
  • Able to communicate effectively with and follow instructions from the study staff
  • Person with an arm circumference between 22 and 42 cm

Exclusion Criteria:

  • Vulnerable subject with regard to regulations
  • Pregnant, parturient or breastfeeding woman,
  • Subject who is deprived of liberty by judicial, medical or administrative decision,
  • Underage subject,
  • Legally protected subject, or subject who is unable to sign the written informed consent form,
  • Subject who is not beneficiary or not affiliated to a social security scheme,
  • Subject within several of the above categories,
  • Subject who refused to participate in the study,
  • Subject in linguistic or psychic incapacity to sign a written informed consent form,
  • Subject in physical incapacity to wear a blood pressure monitor
  • Subject with electrical stimulation by pacemaker
  • Significant tremor that prevents subject from being able to hold still
  • Known sensitivity to medical adhesives, isopropyl alcohol, or ECG electrodes

Study details
    Arrhythmia
    Arrhythmia
    Atrial Fibrillation
    Atrial Fibrillation
    atrial fibrillation (pediatric)
    Cardiovascular Disease
    atrial fibrillation (pediatric)

NCT04464499

Withings

16 February 2024

Step 1 Get in touch with the nearest study center
Message sent successfully.
We have submitted the information you provided to the research team at the location you chose. For your records, we have sent a copy of the message to your email address.
If you would like to be informed of other studies that may be of interest to you, you may sign up for Patient Notification Service.
Sign up

Send a message

Enter your contact details to connect with study team


Email

View email

Phone

Phone country flag

View phone
Investigator Avatar

Primary Contact

First name*
Last name*
Email*
Phone number*
Other language

FAQs

Learn more about clinical trials

What is a clinical trial?

A clinical trial is a study designed to test specific interventions or treatments' effectiveness and safety, paving the way for new, innovative healthcare solutions.

Why should I take part in a clinical trial?

Participating in a clinical trial provides early access to potentially effective treatments and directly contributes to the healthcare advancements that benefit us all.

How long does a clinical trial take place?

The duration of clinical trials varies. Some trials last weeks, some years, depending on the phase and intention of the trial.

Do I get compensated for taking part in clinical trials?

Compensation varies per trial. Some offer payment or reimbursement for time and travel, while others may not.

How safe are clinical trials?

Clinical trials follow strict ethical guidelines and protocols to safeguard participants' health. They are closely monitored and safety reviewed regularly.
Add a private note
  • abc Select a piece of text.
  • Add notes visible only to you.
  • Send it to people through a passcode protected link.